Technipower Systems

LJ Series

E-mail Print PDF

1φ or 3φ Input

3 Models - Single Output - 3000 Watts

Embedded System power systems


40 kHz AC Source

Description

The LJ Series is part of Deltron’s SlimLine3 group of 3U high-power, single-phase or 3-phase power systems. Rated at 3000 watts, these single output models measure only 4.74"H x 3.48”W x 11.09”L. Designed for ease of system installation, field connections are via studs and screw terminals. 48VDC models provide a high-density front-end solution for powering Intermediate Bus Converters (IBCs).

LJ Series modules fit a wide range of high power requirements ranging from heavy duty industrial applications to fault tolerant front-end networking and computing applications. Units can be paralleled for additional power or used in combination with other models to meet multiple output requirements.

Designed to meet applicable NEBS standards, units feature a proven topology coupled with excellent thermal management to achieve outstanding performance and safety. Power Fail, DC Good, Hi Temp and Fan Fail features provide TTL-compatible logic signals for monitoring power supply status. All models are available with redundancy option for parallel or N+1 applications.

LJ Series Rack Systems

The RA300B 3U high, 19”-wide racking system is available for paralleling or N+1 redundant systems. The 5.25”-high by 11.3”-deep rack accommodates up to four LJ Series power systems providing up to 12 kW.

Each power supply plugs into the rack and is securely held in place by removable front panels. Input, output and signal connections are made via rear accessible terminal blocks, studs and headers on each power supply. Racks are designed to accept either EIA or Bellcore NEBS mounting and heavy-duty chassis slides.

40 kHz AC Source

Features

  • 17 watts per cubic inch
  • 80% efficiency
  • 3U high - SlimLine3 package
  • Power Factor Corrected
  • EN 61000-3-2 compliant
  • Meets International Safety Agency Requirements
  • FCC, CISPR Class B EMI
  • IEC, EN Immunity
  • Standard features include:
    Pilot bias
    Power Fail Monitor
    DC Good Signal
    Hi Temp signal
    Fan Fail signal
    Inhibit capability
    Single wire current share
    OVP on all models
    Overload and short circuit protection
    Reverse voltage protection
    Integral cooling fan
    Field terminations with LED indicators
    for AC, DC Good and Hi Temp
  • Options and Accessories include:
    Redundancy with Or-ing diode
    I2C Serial Interface
    3U high racking system
 
You are here: Home Deltron™ Power Supplies LJ Series